Description
Main
| range | TeSys |
|---|---|
| product name | TeSys F |
| product or component type | Contactor |
| device short name | LC1F |
| contactor application | Resistive load |
| utilisation category | AC-1 |
| poles description | 4P |
| power pole contact composition | 4 NO |
| [Ue] rated operational voltage | <= 1000 V AC-1 <= 690 V AC-3 <= 690 V AC-4 <= 460 V DC |
| [Ie] rated operational current | 350 A (at <40 °C) at <= 440 V AC AC-1 |
| [Uc] control circuit voltage | 220 V AC 40…400 Hz |
Complementary
| [Uimp] rated impulse withstand voltage | 8 kV |
|---|---|
| overvoltage category | III |
| [Ith] conventional free air thermal current | 350 A (at 40 °C) |
| rated breaking capacity | 2120 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 2200 A 40 °C – 10 s 1230 A 40 °C – 30 s 950 A 40 °C – 1 min 620 A 40 °C – 3 min 480 A 40 °C – 10 min |
| associated fuse rating | 315 A aM at <= 440 V 400 A gG at <= 440 V |
| average impedance | 0.3 mOhm – Ith 350 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
| power dissipation per pole | 37 W AC-1 |
| mounting support | Plate |
| standards | JIS C8201-4-1 IEC 60947-1 EN 60947-4-1 IEC 60947-4-1 EN 60947-1 |
| product certifications | LROS (Lloyds register of shipping) CB RINA ABS BV DNV RMRoS UL CCC UKCA |
| connections – terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) – busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 240 mm² Power circuit: connector 1 cable(s) 240 mm² Power circuit: bolted connection |
| tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
| control circuit voltage limits | Operational: 0.85…1.1 Uc 40…400 Hz (at 55 °C) Drop-out: 0.15…0.2 Uc 40…400 Hz (at 55 °C) |
| inrush power in VA | 650 VA 40…400 Hz cos phi 0.9 (at 20 °C) |
| hold-in power consumption in VA | 10 VA 40…400 Hz cos phi 0.9 (at 20 °C) |
| heat dissipation | 8 W |
| operating time | 40…65 ms closing 100…170 ms opening |
| mechanical durability | 10 Mcycles |
| maximum operating rate | 2400 cyc/h 55 °C |
| compatibility code | LC1F |