Categories

Latest Posts

TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 500 A - coil 220 V AC

TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 500 A - coil 220 V AC

SKU: LC1F500M7 Categories: , Tag:

Description

Main

range TeSys
product name TeSys F
product or component type Contactor
device short name LC1F
contactor application Motor control
Resistive load
utilisation category AC-1
AC-4
AC-3
poles description 3P
power pole contact composition 3 NO
[Ie] rated operational current 700 A (at <40 °C) at <= 440 V AC AC-1
500 A (at <55 °C) at <= 440 V AC AC-3
motor power kW 250 kW at 380…400 V AC 50/60 Hz (AC-3)
280 kW at 415 V AC 50/60 Hz (AC-3)
295 kW at 440 V AC 50/60 Hz (AC-3)
355 kW at 500 V AC 50/60 Hz (AC-3)
335 kW at 660…690 V AC 50/60 Hz (AC-3)
335 kW at 1000 V AC 50/60 Hz (AC-3)
147 kW at 220…230 V AC 50/60 Hz (AC-3)
80 kW at 400 V AC 50/60 Hz (AC-4)
[Uc] control circuit voltage 220 V AC 40…400 Hz

Complementary

[Uimp] rated impulse withstand voltage 8 kV
overvoltage category III
[Ith] conventional free air thermal current 700 A (at 40 °C)
rated breaking capacity 4000 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current 4200 A 40 °C – 10 s
3200 A 40 °C – 30 s
2400 A 40 °C – 1 min
1500 A 40 °C – 3 min
1200 A 40 °C – 10 min
associated fuse rating 500 A aM at <= 440 V
800 A gG at <= 440 V
average impedance 0.18 mOhm – Ith 700 A 50 Hz
[Ui] rated insulation voltage 1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole 88 W AC-1
45 W AC-3
mounting support Plate
standards EN 60947-4-1
IEC 60947-1
EN 60947-1
JIS C8201-4-1
IEC 60947-4-1
product certifications CSA
CB
RMRoS
ABS
LROS (Lloyds register of shipping)
UL
RINA
BV
DNV
UKCA
connections – terminals Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) – busbar cross section: 40 x 5 mm
Power circuit: lugs-ring terminals 2 cable(s) 240 mm²
Power circuit: bolted connection
tightening torque Control circuit: 1.2 N.m
Power circuit: 35 N.m
control circuit voltage limits Operational: 0.85…1.1 Uc 40…400 Hz (at 55 °C)
Drop-out: 0.3…0.5 Uc 40…400 Hz (at 55 °C)
inrush power in VA 1100 VA 40…400 Hz cos phi 0.9 (at 20 °C)
hold-in power consumption in VA 18 VA 40…400 Hz cos phi 0.9 (at 20 °C)
heat dissipation 18 W
operating time 40…65 ms closing
100…170 ms opening
mechanical durability 10 Mcycles
maximum operating rate 2400 cyc/h 55 °C
compatibility code LC1F
motor power range 250…500 kW at 380…440 V 3 phases
110…220 kW at 380…440 V 3 phases
110…220 kW at 200…240 V 3 phases
250…500 kW at 480…500 V 3 phases
motor starter type Direct on-line contactor
contactor coil voltage 220 V AC standard

Reviews

There are no reviews yet.

Be the first to review “TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 500 A - coil 220 V AC”

Your email address will not be published. Required fields are marked *